GAP FILLER

GAP FILLER 4000

Features & Benefits

  •  Thermal Conductivity: 4.0 W/m-K
  •  Extended working time for manufacturing flexibility
  •  Ultra-conforming with excellent wet-out
  •  100% solids – no cure by-products
  •  Excellent low and high temperature chemical and mechanical stability

Properties

Typical properties of GAP FILLER 4000
Properties Imperial Value Metric Value Test Method
Density (Bulk Rubber) (g/cc) 3.1 3.1 ASTM D792
Color / Part A Blue Blue Visual
Color / Part B White White Visual
Mix Ratio 1:1 1:1 ***
Shelf Life @ 25ºC (months) 5 5 ***
Viscosity / Part A, High Shear (Pa-s) 50 50 ASTM D5099
Viscosity, High Shear (Pa-s) (1) 50 50 ASTM D5099
Typical properties of GAP FILLER 4000
Electrical Imperial Value Metric Value Test Method
Dielectric Constant (1000 Hz) 7.9 7.9 ASTM D150
Volume Resistivity (Ohm-meter) 10^10 10^10 ASTM D257
Flame Rating V-O V-O U.L. 94
Dielectric Strength (V/mil)/(V/mm) 450 18,000 ASTM D149
Dielectric Constant (1000 Hz) 450 450 ASTM D149
Typical properties of GAP FILLER 4000
Thermal Imperial Value Metric Value Test Method
Thermal Conductivity (W/m-K) 4.0 4.0 ASTM D5470
Typical properties of GAP FILLER 4000
Property as Cured Imperial Value Metric Value Test Method
Color Blue Blue Visual
Hardness (Shore A) (2) 75 75 ASTM D2240
Heat Capacity (J/g-K) 0.8 0.8 ASTM D1269
Continuous Use Temp (°F) / (°C) -76 to 392 -60 to 200 ***
Typical properties of GAP FILLER 4000
Deflection (% strain) 10 20 30
Thermal Impedance (°C-in2/W) 0.020" V-O V-O U.L. 94
Typical properties of GAP FILLER 4000
Cure Schedule
Cure @ 25ºC (hrs) (3) 24 24 ***
Cure @ 100ºC (min) (3) 30 30 ***
Working Time @ 25ºC (min) (3) 240 min (4 hrs) 240 min ( 4 hrs) ***
Typical properties of GAP FILLER 4000
Electrical As Cured Imperial Value Metric Value Test Method
Dielectric Constant (1000 Hz) 450 450 ASTM D149
Volume Resistivity (Ohm-meter) 7.9 7.9 ASTM D150
Flame Rating 10^10 10^10 ASTM D257