HI FLOW
Hi-Flow 300P
Features & Benefits
- Thermal impedance: 0.13°C-in2/W (@25 psi)
- Field-proven polyimide film
- -excellent dielectric performance
- -excellent cut-through resistance
- Outstanding thermal performance in an insulated pad
Properties
Properties | Imperial Value | Metric Value | Test Method |
---|---|---|---|
Reinforcement Carrier | Polymide | Polymide | *** |
Color | Green | Green | Visual |
Typical Use Temp (°F) / (°C) | 302 | 150 | *** |
Phase Change Temp (°F) / (°C) | 131 | 55 | ASTM D3418 |
Thickness (inch) / (mm) | 0.004-0.005 | 0.102-0.127 | ASTM D374 |
Elongation (%45° to Warp and Fill) | 40 | 40 | ASTM 882A |
Tensile Strength (psi) / (MPa) | 7000 | 48 | ASTM 882A |
Film Thickness (inch) / (mm) | 0.001-0.002 | 0.025-0.050 | ASTM D374 |
Electrical | Imperial Value | Metric Value | Test Method |
---|---|---|---|
Dielectric Breakdown Voltage (Vac) | 5000 | 5000 | ASTM D149 |
Dielectric Constant (1000 Hz) | 4.5 | 4.5 | ASTM D150 |
Volume Resistivity (Ohm-meter) | 10^12 | 10^12 | ASTM D257 |
Flame Rating | V-O | V-O | U.L. 94 |
Thermal | Imperial Value | Metric Value | Test Method |
---|---|---|---|
Thermal Conductivity (W/m-K) (1) | 1.6 | 1.6 | ASTM D5470 |
Pressure (psi) | 10 | 25 | 50 | 100 | 200 |
---|---|---|---|---|---|
TO-220 Thermal Performance (°C/W) 0.010" | 0.95 | 0.94 | 0.92 | 0.91 | 0.90 |
TO-220 Thermal Performance (°C/W) 0.015" | 1.19 | 1.17 | 1.16 | 1.14 | 1.12 |
TO-220 Thermal Performance (°C/W) 0.020" | 1.38 | 1.37 | 1.35 | 1.33 | 1.32 |
Thermal Impedance (ºC-in2/W) 0.010" | 0.13 | 0.13 | 0.12 | 0.12 | 0.12 |
Thermal Impedance (ºC-in2/W) 0.015" | 0.17 | 0.16 | 0.16 | 0.16 | 0.15 |
Thermal Impedance (ºC-in2/W) 0.020" | 0.19 | 0.19 | 0.19 | 0.18 | 0.18 |